Tuesday, May 30, 2017

Week Eight Update

Last week we touched up on our final report and met to correct our draft where we saw fit.  We created better visuals for our report to represent our data in an easy to read fashion.  This week in lab we would like to take another test run of data with each liquid to finalize our results, and we will make sure to start these tests from the same temperature.  We will also look to translate our report and project into a well designed presentation this week.  Ideally, we will meet a few times this week to practice and refine the presentation.

Here are a few examples of our visuals:
Figure 1: Temperature of Water as a function of Time
Figure 2: Temperature of Acetone as a function of Time.

Tuesday, May 23, 2017

Week Seven Update

Last week we tested our heat pipe again with water and acetone to ensure our previous results were correct. The results remained the same as acetone achieving a higher temperature. Here is a picture of our working heat pipe.
We plan to work on the final draft more this week and add more materials we learn from lab. In next week we plan to triple check our results and work on the final draft. 

Tuesday, May 16, 2017

Week Six Update

Last week we tested our heat pipe using acetone as the heat transfer fluid. It went well, giving us an overall higher temperature at stabilization than using water did.
Here is the data from that test:


Time (sec)
Temperature (°F)
60
115
90
123
120
128
150
131
180
137
210
140
240
144
270
147
300
149
330
153
360
156
390
158
420
160
450
161

We decided not to test methanol like we had planned, as we don't really have the equipment necessary to do it safely. This week we have been working on our draft for our final report. In lab we plan to test our heat pipe again, with water and acetone, to confirm the results we got previously.

Tuesday, May 9, 2017

Week 5 Post

Last week in class we assembled our heat pipe, and tested it using tap water. At first our results were bad, because we were not measuring the temperature at the point where the water was condensing. We also had an issue with our pipe leaking. But we fixed the leak and quickly figured out where we needed to measure from, and got some better data.

Table 1: Temperature of Heat Pipe at Timed Intervals
Time (sec)
Temperature (°F)
30
80
60
85
90
88
120
89
150
93
180
108
210
115
240
114











Next week in class we plan to test using acetone, and then methanol, and will be able to see how they compare with our results for water.

Wednesday, May 3, 2017

Week 4 Update

This week we completed our initial prototype of our heat pipe. We switched our preferred material to Stainless Steel (316) due to the nature of it.  The copper pipe acquired from the shop was too thin to cut a pipe thread, and the thicker stainless was already available to one of our group members.  The stainless is a 1/2 inch pipe with an outside diameter of .840 in.  The pipe thread uses National Pipe Thread (NPT) standards.  The caps for the pipe were obtained from Fastenal and our also Stainless Steel (316).  Teflon tape will be used to secure the threads to stop any passages opening when testing our liquids.